Environment Setup

This page provides reference specifications for the Palette Virtual Machine Orchestrator (VMO) hardware and network resources.

Hardware Resources

The following sections list the hardware requirements for worker nodes and control plane nodes in a VMO cluster.

Worker Nodes

Refer to the following table for the minimum and recommended hardware specifications for the worker nodes of the cluster.

ComponentMinimumRecommendedComments
Form FactorThe server must fit Fiber Channel (FC) adapters and have sufficient Network Interface Cards (NIC).2U Rackmount Chassis
CPUIntel or AMD x64 CPU with 8 coresIntel or AMD x64 CPU with 8 cores
RAM24 GB256 GB or moreAssumes the deployment of 20 VMs per node multiplied by the median RAM per VM.
Network Adapters2 x 10 Gbps
(data + management)
2 x 10 Gbps (data)
2 x 10 Gbps (management)
Pod overlay operates on the management network.
Storage Adapters2 x 16 Gbps FC2 x 16 Gbps FCStorage adapters must support the FC protocol, a high-speed network protocol used for data transfer.
DisksLocal disk for the OS boot (SAN boot is supported)Local disk for the OS bootBoot from SAN requires special consideration due to the multi-path configuration.

Control Plane Nodes

Typically, the cluster control plane nodes do not operate any VMO workloads. As a result, they can have lighter hardware specifications in terms of CPU and RAM. For example, a server with 4 cores and 8 GB RAM is sufficient for a minimum-specification control plane node. The rest of the hardware requirements for control plane nodes remain the same as worker nodes.

ComponentMinimumRecommendedComments
Form FactorThe server must fit Fiber Channel (FC) adapters and have sufficient Network Interface Cards (NIC).2U Rackmount Chassis
Network Adapters2 x 10 Gbps
(data + management)
2 x 10 Gbps (data)
2 x 10 Gbps (management)
Pod overlay operates on the management network.
Storage Adapters2 x 16 Gbps FC2 x 16 Gbps FCStorage adapters must support the FC protocol, a high-speed network protocol used for data transfer.
DisksLocal disk for the OS boot (SAN boot is supported)Local disk for the OS bootBoot from SAN requires special consideration due to the multi-path configuration.

The CPU and RAM requirements for control plane nodes increase with the number of worker nodes and namespaces in the cluster. Refer to the following table for guidance on control plane node sizing.

warning

These recommendations assume that each cluster has at least three control plane nodes.

Worker NodesNamespacesCPU CoresMemory (GB)
1010048
25500416
1001000832
25020001664
500400032128

Network Configuration

Compared to the standard Kubernetes clusters, networking for Palette VMO can require additional configuration, especially if your VMs need to be accessible on the existing VLANs. As this configuration requires bypassing the typical Kubernetes pod networking stack, we use Multus for networking in Palette VMO.

This also implies additional requirements for the host network configuration of worker nodes in order to have valid network targets for the VMs.

Refer to the following table for an example of network configuration.

NetworkVLAN IDNetwork CIDRGateway
Bare Metal Deployment0 (native)192.168.0.0/22
Kubernetes Hosts (management)10172.16.0.0/22
End-user Access (data)2010.20.30.0/1610.20.30.1
Pod OverlayN/A (virtual)100.64.0.0/18
Cluster ServicesN/A (virtual)100.64.64.0/18
Existing VM VLANs21 – 100

MetalLB can use the End-user Access network to publish non-virtualized apps in the following ways:

You can select either approach depending on your network equipment.

tip

We recommend using a dedicated VLAN for end-user access and not sharing it with VLANs used by VMs.

Refer to the following table for an example of a host network configuration, which uses a total of 4 NICs in 2 bonds and fits with our recommended VMO network configuration.

InterfaceTypeContentsVLANCIDRGateway
bond_managementBondenp1s0
enp2s0
Native192.168.0.0/22
bond_management.10VLANbond_management10172.16.0.0/22
bond_dataBondenp1s1
enp2s1
Native
bond_data.20VLANbond_data2010.20.30.0/1610.20.30.1
br0Bridgebond_dataNative

The br0 bridge interface is used as a primary interface by Multus to automatically create VLAN interfaces for VMs. In this scenario, the primary interface must be a bridge, as no other type will work.

This setup also assumes that the physical servers (the worker nodes) have four physical network interfaces that are connected to the switch, as described in the following table.

Physical PortName in OSPurposeSwitchport Configuration
NIC 1, Port 1enp1s0PXE boot for OS deployment
Management network
Trunk (allowing 0, 10)
NIC 1, Port 2enp2s0Management networkTrunk (allowing 0, 10)
NIC 2, Port 1enp1s1Data networkTrunk (allowing 20-100)
NIC 2, Port 2enp2s1Data networkTrunk (allowing 20-100)

For PXE boot, you can use both an untagged or native VLAN 0 network and a tagged network, such as VLAN 5. However, to ensure a successful PXE boot on a tagged network, we recommend setting the native VLAN network to the tagged VLAN ID on the switch port (in our example, this would be 5), so that the PXE boot can work with untagged traffic.

Alternatively, if the server supports UEFI PXE boot and allows you to set the VLAN ID for PXE boot directly, you can also use this option. In this case, you need to adjust the configuration for bond_management to operate the 192.168.0.0/22 CIDR on a bond_management.5 subinterface. However, because it is difficult to achieve PXE boot on a tagged VLAN, we recommend using a native or untagged VLAN for PXE.

The bond_data.20 subinterface provides outbound connectivity, as it has the default gateway. This is the primary way to publish services from container workloads to the end users. If there are any specific data center networks that you want to reach over the bond_management.10 subinterface instead, you can configure them through static routes on the 172.16.0.0/22 subnet in Canonical MAAS. Those routes will be automatically applied by MAAS upon server installation.

For publishing workloads from VMs, you have the following ways:

  • Operating the VM on the pod network like containers and publishing the individual VM ports as Kubernetes services on the bond_data.20 network. In this case, you can use MetalLB to assign IP addresses.

  • Placing the entire VM on a VLAN and using Multus to assign the VM to a VLAN on top of the br0 interface. In this case, it's the responsibility of the VM (for static IPs) or the network (for DHCP) to assign IP addresses.

Limited Alternative

If your setup is limited to two physical network interfaces, you will need to make some adjustments. Assuming the same networks and VLANs are used, consider the following network configuration example (configured through Canonical MAAS).

InterfaceTypeContentsVLANCIDRGateway
bond0Bondenp1s0
enp2s0
Native
bond0.10VLANbond010172.16.0.0/22
bond0.20VLANbond02010.20.30.0/1610.20.30.1
br0Bridgebond0Native192.168.0.0/22

For this setup, it is assumed that the physical servers (worker nodes) are connected to the switch, as described in the following table.

Physical PortName in OSPurposeSwitchport Configuration
NIC 1, Port 1enp1s0PXE boot for OS deployment
Management network
Data network
Trunk (allowing 0, 10, 20-100)
NIC 1, Port 2enp2s0Management network
Data network
Trunk (allowing 0, 10, 20-100)

In this configuration, VLANs 10 (management) and 20 (data) are not available for use by VMs on the br0 interface because the VLAN subinterfaces on the bridge primary interface and VLAN subinterfaces on the bridge are mutually exclusive.

If you need to operate VMs on the same VLAN as either the management (10) or the data (20) VLAN, you can facilitate this by changing the network configuration as follows.

InterfaceTypeContentsVLANCIDRGateway
bond0Bondenp1s0
enp2s0
Native
bond0.10VLANbond010172.16.0.0/22
br0Bridgebond0Native192.168.0.0/22
br0.20VLANbr02010.20.30.0/1610.20.30.1

In this example, VLAN 20 is defined as a subinterface of br0 instead of on bond0. This configuration allows virtual machines to also operate on VLAN 20 without conflicts.